Technical Data
Design Electrical connection at the sideRocker valve with diaphragm seal
Sealing principle Soft
Material in contact with the medium PEEK
Suitable for use with food See supplementary material information
Valve function 2/2-way, closed, monostable
Nominal size 2
Flow direction Reversible
Type of actuation Electric
Type of piloting Direct
Type of reset Mechanical spring
Manual override None
Mounting position optional
Type of mounting With through-hole for M2.5 screw
Electrical connection 1, connection type Cable with plug
Electrical connection 1, connector system Connection pattern H
Electrical connection 1, connection pattern 00995622
Size 16
Grid dimension 17
Fluid connection Flange
Medium Liquid mediaGaseous media
Note on the medium Observe resistance of materials that come into contact with the mediaMaximum particle size 5 µm
Internal volume 110 µl valve with fl. conn.89 µl fluid chamber valve
Media temperature 050
Media temperature for fluids 050
Ambient temperature 050
Storage temperature -2070
Medium pressure -10.87529
Burst pressure 290
Total leakage 0.004
Operational voltage range DC 1224
Permissible voltage fluctuations +/- 10 %
Information on power consumption Low-current phase 1.4 W, high-current phase 5.5 W for 100 ms
Characteristic coil data 12 - 24 V DC: low-current phase 1.4 W, high-current phase 5.5 W
Insulation material class B
Duty cycle 100% in conjunction with holding current reductionObserve the notes on operating the solenoid valves.
Max. switching frequency 4
Note on switching frequency Dependent on the ambient temperature and installation state
Switch-on time for fluids 16
Switching time on gaseous media 12
Standard nominal flow rate (standardised to DIN 1343) 65
Note on standard nominal flow rate In case of a pressure drop of 1 -> 0 bar (gaseous media)
Flow rate Kv 0.8
Note on flow rate Kv For medium waterPressure difference 1 bar
Water flow rate at max. operating pressure 0.07 m³/h1.2 l/min
Symbol 00992884
Material housing PEEK
Material membrane EPDM
Material seals EPDM
Note on materials RoHS-compliant
LABS (PWIS) conformity VDMA24364 zone III
Product weight 50
Degree of protection IP40
Note on degree of protection In assembled state
Instructions on use For indoor use only
Corrosion resistance class CRC 0 - No corrosion stress
Approval RCM trademark
CE mark (see declaration of conformity) To EU EMC DirectiveIn accordance with EU RoHS Directive
UKCA marking (see declaration of conformity) To UK instructions for EMCTo UK RoHS instructions

На Media separated solenoid valve VYKC-F16-M22C-20-PE-H2R

Для заявки пишите в МАХ или Telegram

# #

Приемущества

Flexible nominal widths (1.2 mm/1.6 mm/2.0 mm) with the same size (16 mm)
High-quality materials, therefore also suitable for aggressive media
Minimised heating effect thanks to intelligent holding current reduction
FDA-listed materials
Visual feedback via two LEDs simplifies use
Optionally with holding current reduction
Low energy consumption thanks to efficient actuation

Документы

VYKC_EN.PDF
Datasheet